68233-3 RC Defrost Timer
WR51X10101 or 1399613 Defrost Heater
WR30X10081 Electronic Controlled Ice Maker
Parts Click Here=> Kenmore Elite Model 106.70203990
User Manual Click Here=> Model 106.70203990 Manual
This Model Falls under these Model Numbers also
Kenmore Top Mount Refrigerator
Model Numbers: 10670203990,10670203991, 10670209990, 10670204990, 10670202990, 10670204991, 10670202991, 10670209991
FD955EAW0 Part 407697 Dryer Motor
Friday, October 16, 2009
Wednesday, October 14, 2009
12868513 or 1472681 Control Board
241739701 or 1196804 Digital Control
241739701 or 1196804 Digital Control
Having Problems with the Kenmore 73502 / 73504 / 73509 Bottom Freezer Refrigerator?
That model was made by Maytage and sold to Sears under the name Kenmore. If you would like the service manual Click Here=> PBF2555HEW If you need parts click Here=> PBF2555HEW Or Click Here and enter model PBF2555HEW
That model was made by Maytage and sold to Sears under the name Kenmore. If you would like the service manual Click Here=> PBF2555HEW If you need parts click Here=> PBF2555HEW Or Click Here and enter model PBF2555HEW
12868513 or 1472681 Control Board
Tuesday, October 13, 2009
Thursday, October 8, 2009
Thursday, October 1, 2009
Subscribe to:
Posts (Atom)
452192 Defrost Heater below that Da74-40149D Water Control Valve
WR55X10444 and 1156701 Dispenser Control Board
HOW TO CHECK FOR A BURNED OUT COMPRESSOR
Unplug the refrigerator and remove the back panel that covers the compressor. There should be 3 wires going inside the cover of the compressor. Mark all 3 and mark their location so if compressor is OK you can put them back in same order. The plastic cover may snap on and you may need to squeeze the sides to unlock the cover and sometimes there is a metal clip holding the cover in place. Remove the cover. May look hard but it's simple. There will be three connections under the cover and 2 will go through the start relay. Unplug them leaving the three prongs exposed. They may be marked R =Run, S=Start and C=Common. Set your meter on continuity and then begin by testing 2 at a time until you have checked S to R and R to C an C to S and S to R again. You should get a reading all the way around. If no reading between any of the pairs as you go around you should get no reading between any two the compressor has an open winding and is defective.
Then if it passes that test then touch one probe to R and the other to the copper pipes or clean metal on outside of compressor, then S to metal outside and C to metal outside. If you get a reading this way even just a little. The compressor is a burnout. Then let me know what you find. Thanks, Sea Breeze
NEED HELP AND PHONE OR CHAT HELP? CLICK HERE=> SEA BREEZE
IF MY HELP HAS HELPED YOU, PLEASE CONSIDER A DONATION
67003753 Dual Water Control Valve 67005154 Dual Water Control Valve WR50X10068 Defrost Thermostat TESTING FOR A BURNED OUT COMPRESSOR PART 1 TESTING FOR A BURNED OUT COMPRESSOR PART 2